MÁY ĐO KHÍ CO2 TINH KHIẾT ZAHM & NAGEL SERIES 10000

Model SERIES 10000

Hãng sản xuất: ZAHM & NAGEL – Mỹ

 

Description:

 
The Purity Tester consists of a caustic reservoir and calibrated absorption burette mounted to a PVC polished frame. The reservoir and burette are held to the frame with two neoprene covered mounting bands that are adjustable from the rear side of the frame. The absorption burettes are available in five different calibrations, with the standard burette graduated in tenths of one percent, the total being one percent of the volume of the burette. The caustic reservoir (10100) has a line indicating the level to which caustic solution should be added, which volume is slightly in excess of the capacity of the absorption burette. The line drawings should be used for identification of the Purity Tester parts. When inquiring about our gas purity testers, please specify which absorption burette you require.
 
Operating Instructions:
 
Caution: Caustic solution is used in the operation of this instrument. This solution may cause severe burns to the operator if not handled with care. Wear goggles and protective clothing while operating this instrument.
 
Preparation of Caustic Solution:
 
A 20% solution of either Potassium Hydroxide or Sodium Hydroxide is recommended for air testing*. To make a 20% solution slowly add 100 grams of Potassium or Sodium Hydroxide crystals to 500 cc's of distilled water and store in a sealed jar. The Hydroxide solution may also be purchased from any laboratory or chemical supply company. *A weaker solution may be used, but the tests will take longer and fewer tests can be performed.
 
To Operate:
 
1. Attach a hose from the CO2 gas supply that is to be tested to the nipple of the absorption burette. Use care when attaching the hose so as not to break the calibrated stem of the absorption burette. If using the 1/100th calibrated burette (10102) place your finger on top of the stem and push gently downward onto the support block to prevent the stem from breaking when attaching the hose. Make sure that the gas supply is regulated to below 10 psi before releasing gas into the Purity Tester.
 

2. Open both cocks (5005) and allow the gas to sweep through the absorption burette and caustic reservoir to completely displace air in the glassware. If preferred, the bulb may be first filled with water and the water displaced with the gas to be tested.

 

3. After the sample has been taken, close the cock on the absorption burette first and then close the cock on the caustic reservoir.

4. Pour the caustic solution into the reservoir to the line indicated on the bulb (approximately 105 cc).

 

5. Open the cock on the caustic reservoir and allow the solution to flow down into the absorption burette. Absorption of the CO2 gas now takes place until only air in the sample remains, the small bubble of which may be moved around by tilting the Purity Tester slightly, thereby insuring complete absorption of the gas.

 

6. Close the cock on the caustic reservoir and turn the instrument 90 degrees so that it rests on its other frame side. In this position, the unabsorbed gas enters the calibrated neck where the volume is directly indicated. The percentage purity of CO2 gas is 99%. plus 1/10 of 1% for each division as indicated by the level above the bottom graduation (Using the standard absorption burette #10101). There are our other types of absorption burettes available which are listed below.

 

7. After the test is completed, empty the caustic solution from the Purity Tester. Place the Purity Tester over a container and open both cocks to allow the caustic to drain out. Rinse out all traces of caustic with warm water and dry the glassware before returning the tester to its case.

 

Absorption Burettes Available:

 

P /N

Graduated In

Scale:

10101

0.10%

99 to 100%

10102

0.01%

99 to 100%

     
 

1.00%

79 to 99%

10103

1.20%

99 to 100%

10104

1.00%

50 to 100%

10105

0.10%

95 to 100 %

 

 

 

10001  Standard Tester W/Stand, Bands, Reservoir & Burette (99 to 100% In 0.1% increments)


10101  Calibrated Absorption Burette (99 to 100%In 0.1%)


10100  Caustic Reservoir


5005    Teflon Stopcock


10107  Rubber Covered Band W/Nut (Fits #10101 Burette)


10109  Rubber Covered Band W/Nut (Fits #10100 Reservoir)


10110  Frame - 2Pc W/Center Block


10113  Metal Case


10114  Plastic Connector

 

 
10003     Tester W/Stand, Bands, Reservoir & Burette (99 to 100% In 0.01%)

10102     Calibrated Absorption Burette (99 to 100%In 0.01%)

10100     Caustic Reservoir

5005       Teflon Stopcock

10108     Rubber Covered Band W/Nut (Fits #10102 Burette)

10109     Rubber Covered Band W/Nut (Fits #10100 Reservoir)

10111     Frame - 2Pc W/Center Block and support block

10113     Metal Case

10114     Plastic Connector
 

Xem thêm các loại Thiết bị đo hàm lượng khí giá tốt nhất:

 

 

CÔNG TY TNHH THIẾT BỊ VÀ CÔNG NGHỆ WICO

Địa chỉ: Số 122-A3, Khu đô thị Đại Kim, Phường Định Công, Q Hoàng Mai, TP Hà Nội

Hỗ trợ 24/7: 0968.406.636    ----   0911.373.488  ( Mr. Tú )

Email: thietbiwico@gmail.com

 

 
 

Danh mục sản phẩm

Hỗ trợ trực tuyến

Tư vấn trực tuyến

Tư vấn trực tuyến - 096.840.6636

Mr. Tú

Mr. Tú - 096.840.6636

Mr.Tú

Mr.Tú - 096.840.6636

Máy đo độ pH (207)

Thống kê truy cập

  • Đang online 70
  • Hôm nay 9652
  • Hôm qua 6404
  • Trong tuần 199015
  • Trong tháng 781171
  • Tổng cộng 9293055

Lò Nung (453)

      CÔNG TY TNHH THIẾT BỊ VÀ CÔNG NGHỆ WICO

                                             WICO TECHNOLOGY CO., LTD

     Trụ sở chính: Số 122-A3 khu đô thị Đại Kim, P Định Công, Q Hoàng Mai, TP Hà Nội

CN HCM: Số 103 Đặng Thuỳ Trâm (Đường Trục), Phường 13, Quận Bình Thạnh, TP HCM

  Hotline: 096.840.6636 - 0911.373.488 | Mr.Tú                  Emailthietbiwico@gmail.com

Top

  096.840.6636 Mr.Tú